Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Keysight (Agilent/HP) 8753ES/ET RF Vector Network Analyzer, 30 kHz – 3/6 GHz

Keysight (Agilent/HP) 8753ES/ET RF Vector Network Analyzer, 30 kHz – 3/6 GHz

Product Documentation

Description

The 8753ES RF vector network analyzers perform complete characterization of RF components. It is a flagship network analyzer originally released by Hewlett Packard and carried over under the Agilent Technologies and recently to Keysight Technologies.

Features of the Keysight (Agilent/HP) 8753ES/ET:

  • 30 kHz to 3 or 6 GHz
  • Frequency and power sweeps
  • Available in 50- and 75-ohm
  • Optional time-domain, harmonics measurement, .configurable test set, delete test set
  • Optional Electronic calibration module (ECal)

Contact TestWorld today for the best price on a Keysight (Agilent/HP) 8753ES/ET RF Vector Network Analyzer, 30 kHz – 3/6 GHz.

Explore Financial options to find a cost management solution best for your company:

Main Configurations of the Keysight (Agilent/HP) 8753ES/ET:

  • Transmission/reflection measurements
    • Agilent 8753ET network analyzer
    • Test-port return cable(s), 50 ohms
    • Calibration kit for applicable connector type
  • Full S-parameter measurements
    • Agilent 8753ES network analyzer
    • Test-port return cables, 50 or 75 ohms
    • Calibration kit for applicable connector typeS
  • System with user-selected test set
    • Agilent 8753ES network analyzer
      • Option 011 delete built-in test set
    • S-parameter test set
    • Test port return cables for selected test set
    • Calibration kit for applicable connector type

Configurable Options for the Keysight (Agilent/HP) 8753ET:

A standard Agilent/HP 8753ET covers 300 kHz to 3 GHz, includes a built-in transmission/reflection test  set, and has two 50 ohm type-N female test ports. Included with each instrument is a manual set which includes an installation and quick start guide, user’s guide, reference guide, programmer’s guide, example programs CD-ROM, and a CD-ROM containing the manual set (Available digitally above). Instruments include a 1-year warranty on used and refurbished units.

  • Network analyzer options
    • Option 002: harmonic measurement capability – Provides measurements of swept second and third harmonic responses. Option 006 extends harmonic measurement capability to 6 GHz.
    • Option 004: step attenuator – Extends source output power range from –85 to +10 dBm.
    • Option 006 : 6 GHz frequency extension – Provides source and receiver operation to 6 GHz.
    • Option 010 : time-domain capability –  For viewing reflection and transmission responses in time or distance domain.
    • Option 1D5: high-stability frequency reference –  Provides improved frequency accuracy over time and with temperature variation.

Configurable Options for the Keysight (Agilent/HP) 8753ES:

A standard 8753ES covers 30 kHz to 3 GHz, includes a built-in S-parameter test set, and has two 7-mm test ports. Included with each instrument is a manual set which includes an installation and quick start guide, user’s guide, reference guide, programmer’s guide, example programs CD-ROM, and a CD-ROM containing the manual set. Instruments include a 1-year warranty on used and refurbished units.

  • Network analyzer options
    • Option 002: harmonic measurement capability – For measuring swept second and third harmonic responses. Option 006 extends harmonic measurement capability to 6 GHz.
    • Option 006: 6 GHz frequency extension – Provides source and receiver operation to 6 GHz. Do not order Option 006 with Option 075.
    • Option 010: time-domain capability – For viewing reflection and transmission responses in time or distance domain.
    • Option 011: deletes built-in test set – Removes test set components and allows direct access to the source output power and the R, A, and B receiver inputs via type-N Female connectors. Source start frequency is limited to 300 kHz for units that do not have Option 006. Do not order Option 011 with Option 014 or 075.
    • Option 014: configurable test set – Adds SMA connectors on front panel for access to various source output and receiver input signal paths, including direct access to receivers. When jumpers are in place, the analyzer performs like a standard 8753ES except that maximum source output power is reduced by 2 dB. Do not order Option 014 with Option 011 or 075. This option is not available as an upgrade kit, it must be purchased at time of initial instrument order.
    • Option 075: 75-ohm impedance – Replaces the standard 50 ohm test set with a 75 ohm test set. Test ports are 75-ohm type-N female connectors. Do not order Option 075 with Option 006, 011, or 014.
    • Option 1D5: High-stability frequency reference – Provides improved frequency accuracy over time and with temperature variation.

The following special options are available to customize the 8753ES for particular applications. Please contact Agilent for a quote on these options, to obtain information on expected instrument performance, or to request other special configurations.

  • Option H16: low noise floor – Adds switches that allow the port 2 coupler to be reversed, so that the forward transmitted signal travels along the through path in the coupler instead of the coupled path, increasing the forward dynamic range by about 12 dB while decreasing the dynamic range in the reverse direction by about 15 dB.
  • Option H39: three-port test set – Test set has an added coupler and switching to provide three 50-ohm type-N female test ports for measuring all nine S-parameters of a three-port device.
  • Option H68: 6.8 GHz operation – Extends operation to 6.8 GHz. Performance above 6 GHz is not specified (typical only).
  • Option H85: high-power test set – Provides jumpers to allow the user to add an external power amplifier to provide up to 20 watts (+43 dBm) of power at the test ports, and
    high-power attenuators or isolators for higher input power handling. The standard solid-state transfer switch is replaced by a mechanical transfer switch to handle higher output power, and step attenuators are added between the couplers and samplers to prevent receiver overload. Test ports are 3.5 mm, and the start frequency of this test set is 50 MHz.

Calibration Kits for the Keysight (Agilent/HP) 8753ES/ET:

  • Agilent/HP 85031B 7-mm calibration kit
  • Agilent/HP 85032B 50-ohm type-N calibration kit.
  • Agilent/HP 85033D 3.5-mm calibration kit
  • Agilent/HP 85038A 7-16 calibration kit
  • Agilent/HP 85038F 7-16 calibration kit (female standards)
  • Agilent/HP 85038M 7-16 calibration kit (male standards)

RF Electronic Cal Modules for the Keysight (Agilent/HP) 8753ES/ET:

  • Agilent/HP 85097B: VNA interface kit and software
  • Agilent/HP 85091C: 7-mm RF ECal module
  • Agilent/HP 85092C: 50-ohm type-N RF ECal module
  • Agilent/HP 85093C: 3.5-mm RF ECal module
  • Agilent/HP 85098C: 7-16 RF ECal module
  • Agilent/HP 85029B: 7-mm verification kit

Reviews

There are no reviews yet.

Be the first to review “Keysight (Agilent/HP) 8753ES/ET RF Vector Network Analyzer, 30 kHz – 3/6 GHz”