The Astro-Med Dash 18X 18 Channel Data Recorder gives users the functionality of a scope, meter, data recorder, datalogger and audio recorder in one system with the footprint of a laptop computer with 18 universal inputs for voltage, thermocouple and bridge signals. The Astro-Med Dash 18X’s large real-time waveform display, internal hard drive for capturing data, integral PC connectivity and optional chart recorder, give users the ability to view data in any format that they want. With audio and video snapshot recording – synchronized to waveform data – the Astro-Med Dash 18X ensures that users will capture all aspects of the test. The Astro-Med Dash 18X captures 18 channels of data continuously to a dedicated hard drive at a sample rate of 100 kHz per channel, allowing users to capture the details in high-speed glitches or transients. For long-term trend recording, the Dash 18X allows users to set the sample rate as low as one sample per minute for days, weeks or even months of recording. The flexible Dash 18X allows users to choose the sample rate that is best for the application.
Three different data acquisition modes of the Astro-Med Dash 18X 18 Channel Data Recorder make it adaptable for any application. Real-time recording mode displays waveforms while capturing to the hard drive. Signals are displayed on the large, color display, giving instant data visibility. Scrolling waveforms show exactly what signals are doing in real-time. Use the scope mode for high-speed signals requiring greater timebase resolution. Scope mode gives a detailed, real-time view of high frequency signals while capturing data to the hard drive in the background. Traditional scope controls give the quickest and easiest way to look at high-speed data. Acquire/review mode is ideal for applications where immediate access to captured data is important. It allows users to look back at previously captured data without interrupting real-time recording.
Contact TestWorld today for the best price on a Astro-Med Dash 18X 18 Channel Data Recorder.
Explore Financial options to find a cost management solution best for your company:
Astro-Med Dash 18X 18 Channel Data Recorder Specifications:
Color Display | |
Type | Active matrix color LCD (TFT) with 17″ viewing area |
Resolution | 1280 x 1024 |
Touch | Full-screen, resistive |
Functions | User interface with touch-based icons and menus; Real-time waveform monitoring; Review previous waveform records while recording; Overlay numeric values in Engineering Units |
Interface | |
Ethernet | 10/100BaseT |
DVD | Supports archive of data to CD-R, CD-RW, DVD-R, DVD+R & DVD+RW |
VGA | For displaying data on an external monitor |
USB 1.1 | For external peripherals and file export |
Analog Input Boards | |
Maximum Boards | 3 |
Maximum Waveforms | 18 |
A/D | 14 bit |
Standard Event Inputs | |
Number of Inputs | 8 |
Connector | D-shell (9-pin) |
Input Type | TTL with pull-up (0 to 5VDC) |
Response | Detects if duration is greater than 0.01 msec |
Real-time Signal Processing | |
Filters | Low Pass Stops: 1 Hz to 10,000 Hz; High Pass Starts: 0.1 Hz to 100 Hz; Notch: 50 or 60 Hz center |
RMS | Time constant selectable from 0.02 to 2 seconds |
Frequency to Voltage | 5 Hz to 20 kHz, +/- 0.05% of measurement + 0.1 Hz |
Cross-Channel | Sum, Difference, Ratio, Product (Power) |
Real-time Signal Testing | |
Basic | All active signals monitored simultaneously |
Test Types | Tests include window, slope/level, slew and event pattern |
Outputs | Result available for alarms, trigger, abort and external TTL |
Data Capture | |
Recording Method | Internal 73 Gbyte hard drive |
Max. Rate | 100,000 samples/second per channel (all channels) |
Min. Rate | 1 sample/minute |
Dual Rate | Second slower rate available when no trigger is used |
Total Capacity | 16 billion samples |
Max. Record | 2 billion samples |
Header | Information on units, range, sample rates, etc. saved with data |
Events | All standard event inputs captured with waveforms |
Trigger Point Lock | Amounts of pre- and post-trigger is user adjustable |
Auto Re-arm | Allows automatic stacking of captures |
Auto Playback | Yes |
External Sample Rate | TTL sample clock up to 40,000 Hz |
Signal Conditioner Specifications (General) | |
Channels per Module | 6 |
Isolation | 250 Vrms (iso-common to chassis and other iso-commons) |
Bandwidth | 12 kHz (-3dB) |
Input Coupling | DC |
Zero Suppression | Yes |
User Engineering Units | Yes |
Calibration | Semi-automated to external reference |
Single Ended Voltage Input | |
Input Type | Isolated, single-ended |
Connector | Guarded banana jack |
Max. rated input | +/- 250 Vrms |
Max. transient input | +/- 400 V |
Specified ranges | 40 to 400 VFS; 4 to 40 VFS; 0.4 to 4VFS |
Accuracy (25°C) | +/- 0.5% of attenuator |
Min. Input Impedance | 1 Megohm |
Differential Voltage Measurements (use for bridge measurements) | |
Input Type | Isolated, differential |
Connector | Screw terminal header |
Absolute Max. Input | +/- 40 V differential |
Measuring Ranges | 200 to 1600 mVFS; 50 to 500 mVFS; 5 to 50 mVFS |
Accuracy (25°C) | +/- 0.5% of attenuator |
Min. Input Impedance | 200 kOhm |
CMR at 60 Hz | > 60dB |
Auto Balance | Yes, limited to maximum span |
Thermocouple Measurements | |
Input Type | Isolated, differential with screw terminal header connector |
Absolute Max. Input | +/- 40 V |
Specified Range | Type J: 0 to 760 °C Type K: 0 to 1370 °C Type T: -160 to 400 °C Type E: -100 to 870 °C Type N: 0 to 1300 °C |
Accuracy (25°C) | 0.5% of measurement + 2 °C |
Bandwidth | 10 Hz (-3dB) |
Intrinsic Noise | 0.5 °C (1 Hz filter) |
Linearization | NIST polynomial |
Units | °C or °F |
Excitation | |
Connector | Screw terminal header |
Excitation | Isolated 10V @ 20 mA |
Adjustable | 0.1 to 10 V |
Frequency Measurements | |
Method | Zero-crossing, channels 1, 7 and 13 only |
Signal Amplitude | Peak-to-peak minimum is 20% of attenuator |
Hysteresis | Yes |
Removable Drive | |
Type | DVD+R |
Format | MSDOS® format |
Function | Setup files, software upgrades, data transfer/archive |
Power | |
Input voltage range | 100 to 250 VAC |
Frequency Range | 47 Hz to 63 Hz |
Power Consumption | 300 W maximum |
Compliance | |
Safety | EN 61010-1 |
EMC | FCC Class A, EN 61326 |
Power Harmonics | IEC1000-3-2 |
Physical | |
Enclosure | Aluminum |
Dimensions | 16.1″ L x 15.1″ W x 6.4″ H |
Weight | 29 lbs. |
Environmental | |
Operating Temperature | 5 to 40 °C (40 to 105°F) |
Non-operating Temperature | -20 to 60 °C (-4 to 140 °F) |
Operating humidity | 10% to 90%, non condensing |
Optional Chart Recorder – Model SCR-18 | |
Chart Width | 11″ |
Max. Chart Speed | 50 mm/sec |
Optional DC Input Power – Model PIM-18 | |
Input Range | 9-18 VDC |
Input Power | 200 W max |
Fuse | User replaceable 25 A |
Optional DC Input Power – Model PIM-18A | |
Input Range | 20-32 VDC |
Input Power | 240 W max |
Fuse | User replaceable 10 A |