SDA 8 Zi Series SDA 816 Zi Serial Data Analyzers are based on the WaveMaster 8 Zi Series oscilloscope and are equipped with double the standard memory to capture more unit intervals in the eye diagram. They include an enhanced high-speed serial pattern trigger that operates on up to 80 bit patterns and at speeds up to 3.125 Gb/s. Whether debugging eye pattern or other compliance test failures, the SDA 8 Zi Series rapidly isolates the source of the problem in your design. – Display Eye Pattern, TIE, Bathtub Curve and Jitter Histogram on the screen at the same time – Create Eye Patterns utilizing the full memory for maximum statistical significance – 100 times faster Eye Diagram creation – Gain insight with IsoBER and Mask Violation Locator tools

Key Features

  •  Up to 30 GHz bandwidth and
    80 GS/s sample rate
  •  The industry’s only true hardware
    14.1 Gb/s serial trigger
  •  Low Jitter Measurement Floor and
    exceptional timebase stability
  •  Comprehensive set of serial data
    analysis, debug, validation and
    compliance tools
  •  Integrated 50 Ω and 1 MΩ inputs
    for true connection and probing
    flexibility
  •  Integrated standard and custom
    measurements and math functions
    for unrivaled analysis capability
  •  Multi-lane serial data eye, jitter and
    crosstalk analysis
  •  Real-time de-embedding,
    emulation, and equalization

Specification

Vertical System

Analog Bandwidth (Max) 13 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input) 13 GHz
(≥10 mV/div)
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 3.5 GHz
(≥10 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 500 MHz (typical, ≥2 mV/div)
Rise Time (10-90%, 50 Ω) 32.5 ps
(test limit, flatness mode)
Rise Time (20-80%, 50 Ω) 24.5 ps
(flatness mode)
Input Channels 4 (Any combination of ProLink and ProBus inputs)
Bandwidth Limiters 20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz, 8 GHz
Input Impedance ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div
ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling ProLink Inputs – 50 Ω: DC, GND
ProBus Inputs – 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage 50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div
50 Ω (ProBus): ±5 Vmax, 3.5 Vrms
1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC)
Channel-Channel Isolation DC to 10 GHz: 50 dB (>315:1)
10 to 15 GHz: 46 dB (>200:1)
15 to 20 GHz: 40 dB (>100:1)
(For any two ProLink input channels, same or different v/div settings, typical)
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity 50 Ω (ProLink): 2 mV-1 V/div, fully variable (2-9.9 mV/div via zoom)
50 Ω (ProBus): 2 mV-1 V/div, fully variable; 1 MΩ (ProBus): 2 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V
Vertical Noise Floor (50 mV/div) 1.80 mVrms (typical)
Offset Range 50 Ω (ProLink):
±500 mV @ 2-100 mV/div
±4 V @ >100 mV/div -1 V/div
50 Ω (ProBus):
±750 mV @ 2-100 mV/div
±4 V @ >100 mV/div -1 V/div
1 MΩ:
±1V @ 2-140 mV/div
±10V @ 142mV-1.40V/div
±100V @ 1.42V-10V/div
DC Vertical Offset Accuracy ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit)