Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Teledyne LeCroy – PP007-1 500 MHz Passive Probe

Teledyne LeCroy – PP007-1 500 MHz Passive Probe

Category:

Description

The small probe is optimized for maximum waveform fidelity, including high frequency signal components, in a rugged probe suitable for every day. The input capacitance of the probe is very low for a passive probe to minimize loading of high frequency signals. However, keeping any resonance beyond the passband also requires low inductance in the interconnections. Probes with limited interconnection accessories often force the user to extend

Feature

  • Teledyne LeCroy’s current probes cover measurement requirements up to 500 A. The line is made up of five current probes with bandwidths to 100 MHz, current measurements to 500 A and sensitivities down to 10 mA/div. These probes can be used in a wide range of applications including electric vehicles, three-phase systems, power electronics, motor drives, and general-purpose current measurements. They can be used in conjunction with voltage probes to make instantaneous power measurements. Teledyne LeCroy ProBus interface can be used for probe detection, automatic scale factor adjustment, and probe power.
  • Teledyne LeCroy’s low-voltage differential probes cover frequency ranges to 1.5 GHz with high signal fidelity. These probes offer a choice between 6 low-voltage active-differential probes with bandwidth coverage up to 1.5 GHz. High-input R and low-input C (probes from 3.5 pF to less than 1 pF) enable high performance with low loading. These probes can be used in a wide range of applications including automotive, serial buses, and general purpose use. Each probe is supplied with a full set of standard accessories.
  • Teledyne LeCroy’s high-voltage differential probes feature frequency coverage up to 100 MHz and voltage to 1,400 V. They are active differential probes with bandwidth coverage up to 100 MHz and high voltage input up to 1,400 V peak. High-input R and low-input C enable high performance with low loading. These probes can be used in a wide range of applications including automotive, power electronics, and floating voltage measurements. Each probe is supplied with a full set of standard accessories.Teledyne LeCroy’s high-voltage probes feature voltage coverage up to 6 kV, as well as a bandwidth to 400 MHz. High-input R of 50 MOhms and low-input C of < 6 pF enable high performance with low loading. The probes allow a wide range of applications including electric vehicles, power electronics, and general high-voltage measurements. All fixed attenuation probes have automatic scale factor adjustment when connected to a Teledyne LeCroy oscilloscope. Each probe is supplied with a full set of standard accessories.
  • Teledyne LeCroy’s active probes cover frequency ranges to 4 GHz with high signal fidelity, with four active probes featuring bandwidth coverage from DC to 1 GHz, 1.5 GHz, 2.5 GHz, and 4 GHz. These probes feature high 1 MOhm Input R and low 0.9 pF capacitance (0.6 pF on 4 GHz probe) to preserve signal fidelity. Low circuit loading is ideally suited for probing high-frequency signals. Each probe is supplied with a full set of standard accessories with additional accessories available.

Specifications

Electrical Characteristics

Bandwidth (Probe Only) 500 MHz
Bandwidth (Probe Only) 500 MHz
Input Resistance 10 MΩ
Input Resistance 10 MΩ
Input Capacitance 11 pF
Input Capacitance 11 pF
Maximum Input Voltage 500 V
Maximum Input Voltage 500 V
Attenuation 10:1
Attenuation 10:1
Coupling AC 1 MΩ, DC 1MΩ, GND

Environmental and Safety

Operating Temperature 0 °C to 50 °C
(32 °F to 122 °F)
Humidity 80% Max up to 31 °C
40 % Max at 50 °C
Max Altitude 2000 m
(6562 ft)

Physical Dimensions

Probe Diameter 5 mm
Cable Length 1.2 m
(3.94 ft)

General Characteristics

Interface BNC
Attenuation Sense Pin Yes
Recommended Oscilloscope 9300
LC
WavePro 900
WavePro 7000(A)

 

Reviews

There are no reviews yet.

Be the first to review “Teledyne LeCroy – PP007-1 500 MHz Passive Probe”