Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Teledyne LeCroy – AP015 30 A Current Probe

Teledyne LeCroy – AP015 30 A Current Probe

Description

Teledyne LeCroy – AP015 current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combi-nation of Hall effect and transformer technology, LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
Many current probes require external power supplies or amplifiers to display
a waveform on the oscilloscope screen. All LeCroy current probes are powered through the LeCroyProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for Degauss

and Autozero functions to be done directly from the oscilloscope with
a single button press.
Teledyne LeCroy – AP015Specifications
Electrical Characteristics
  • System Bandwidth: DC to 50 MHz
  • Max. DC Current: ±30 A
  • Max Peak Pulse Current: ±50 A with pulse width < 10 s.
  • Offset Range: ±100 A maximum*
  • Output Sensitivity: 10 mA/div to 10 A/div
  • DC Accuracy (at 250C):±1% of reading to 5 A.
  • ±2% of reading to 30 A.
  • Rise Time:< 7 nsdi/dt
  • Tracking: > 1.6 A/ns
  • External Field Rejection:75 dB at DC.
  • Insertion Impedance:< 0.06 ohms at 5 MHz
  • * Note: depends of the oscilloscope used

General Characteristics

  • Operating Temperature:00C to 400C
  • Max. Conductor size: 5 mm
  • Cable Length:2m.
  • Interface:ProBus, 1 M ohm only.
  • Weight: 300 gr
  • Usage Environment: Indoor
  • Maximum Altitude:2000 m.
  • Maximum Relative Humidity: 80 % (maximum 310C)
  • Calibration:Certificate supplied
Teledyne LeCroy – AP015 Applications
LeCroy current probes are available in a wide range of models for a wide range of applications. The full range of LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 10 mA/div. Multiple current probes can be used together to make measurements

on three-phase systems, or a single current probe can be used with a
voltage probe to make accurate instantaneous power measurements. LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.

Reviews

There are no reviews yet.

Be the first to review “Teledyne LeCroy – AP015 30 A Current Probe”