Keysight (Agilent) E4980AL Precision LCR Meter 20 Hz to 300 kHz/500 kHz/1 MHz

Keysight (Agilent) E4980AL Precision LCR Meter 20 Hz to 300 kHz/500 kHz/1 MHz

Description

The Keysight (Agilent) E4980AL precision LCR meter is an industry standard LCR meter that provides the best combination of accuracy, speed, and versatility for a wide range of component measurements. The frequency upgrades provide a solid investment option and asset utilization.

Offering fast measurement speed and outstanding performance at both low and high impedance ranges, the Keysight (Agilent) E4980AL is the basic tool for general R&D and manufacturing test of components and materials. LAN, USB and GPIB PC connectivity enhances your design and test productivity.

Features of the Keysight (Agilent) E4980AL Precision LCR Meter:

  • Frequency: 20 Hz to 300 kHz/500 kHz/1 MHz, with 4-digit resolution in any range
  • Basic accuracy: 0.05% basic accuracy with superior measurement repeat-ability at low and high impedance
  • 100 uV to 2 Vrms, 1 uA to 20 mA variable test signal
  • DC bias 1.5/2 V
  • Auto-level control
  • DC resistance
  • 201 points list sweep
  • Versatile PC connectivity (LAN, USB, and GPIB)
  • Upgradability (frequency, handler interface, scanner interface)

Measurement Characteristics of the Keysight (Agilent) E4980AL Precision LCR Meter:

  • Measurement Parameters:
    • Impedance parameters |Z|, |Y|, Ls, Lp, Cs, Cp, Rs, Rp, X, G, B, D, Q, Øz [°], Øz [rad], Øy [°], Øy [rad], User defined parameter (A maximum of four parameters can be displayed at one time.)
  • Measurement Range:
    • Impedance parameters 140 mΩ to 4.8 kΩ (Frequency = 1 MHz, Averaging factor = 8, Measurement time mode = 3, Oscillator level = 1 dBm, Measurement uncertainty ≤ ± 10%, Calibration is performed within 23 °C ± 5 °C, Measurement is performed within ± 5 °C from the calibration temperature)

Contact TestWorld today for the best price on the Keysight (Agilent) E4980A Precision LCR Meter, 20 Hz to 2 MHz.

Explore Financial options to find a cost management solution best for your company:

Configurable Options for the Keysight (Agilent) E4980AL LCR Meter:

E4980AL-030 20 Hz to 300 kHz with DCR Measurement
E4980AL-03A 20 Hz to 300 kHz with DCR Measurement, ISO 17025 calibration
E4980AL-03B 20 Hz to 300 kHz with DCR Measurement, ANSI Z540 calibration
E4980AL-03C 20 Hz to 300 kHz with DCR Measurement, Handler
E4980AL-03D 20 Hz to 300 kHz with DCR Measurement, Handler, ISO 17025 calibration
E4980AL-03E 20 Hz to 300 kHz with DCR Measurement, Handler, ANSI Z540 calibration
E4980AL-03F 20 Hz to 300 kHz with DCR Measurement, Scanner
E4980AL-03G 20 Hz to 300 kHz with DCR Measurement, Scanner, ISO 17025 calibration
E4980AL-03H 20 Hz to 300 kHz with DCR Measurement, Scanner, ANSI Z540 calibration
E4980AL-03J 20 Hz to 300 kHz with DCR Measurement, Handler/Scanner
E4980AL-03K 20 Hz to 300 kHz with DCR Measurement, Handler/Scanner, ISO 17025 calibration
E4980AL-03L 20 Hz to 300 kHz with DCR Measurement, Handler/Scanner, ANSI Z540 calibration
E4980AL-050 20 Hz to 500 kHz with DCR Measurement
E4980AL-05A 20 Hz to 500 kHz with DCR Measurement, ISO 17025 calibration
E4980AL-05B 20 Hz to 500 kHz with DCR Measurement, ANSI Z540 calibration
E4980AL-05C 20 Hz to 500 kHz with DCR Measurement, Handler
E4980AL-05D 20 Hz to 500 kHz with DCR Measurement, Handler, ISO 17025 calibration
E4980AL-05E 20 Hz to 500 kHz with DCR Measurement, Handler, ANSI Z540 calibration
E4980AL-05F 20 Hz to 500 kHz with DCR Measurement, Scanner
E4980AL-05G 20 Hz to 500 kHz with DCR Measurement, Scanner, ISO 17025 calibration
E4980AL-05H 20 Hz to 500 kHz with DCR Measurement, Scanner, ANSI Z540 calibration
E4980AL-05J 20 Hz to 500 kHz with DCR Measurement, Handler/Scanner
E4980AL-05K 20 Hz to 500 kHz with DCR Measurement, Handler/Scanner, ISO 17025 calibration
E4980AL-05L 20 Hz to 500 kHz with DCR Measurement, Handler/Scanner, ANSI Z540 calibration
E4980AL-100 20 Hz to 1 MHz with DCR Measurement
E4980AL-10A 20 Hz to 1 MHz with DCR Measurement, ISO 17025 calibration
E4980AL-10B 20 Hz to 1 MHz with DCR Measurement, ANSI Z540 calibration
E4980AL-10C 20 Hz to 1 MHz with DCR Measurement, Handler
E4980AL-10D 20 Hz to 1 MHz with DCR Measurement, Handler, ISO 17025 calibration
E4980AL-10E 20 Hz to 1 MHz with DCR Measurement, Handler, ANSI Z540 calibration
E4980AL-10F 20 Hz to 1 MHz with DCR Measurement, Scanner
E4980AL-10G 20 Hz to 1 MHz with DCR Measurement, Scanner, ISO 17025 calibration
E4980AL-10H 20 Hz to 1 MHz with DCR Measurement, Scanner, ANSI Z540 calibration
E4980AL-10J 20 Hz to 1 MHz with DCR Measurement, Handler/Scanner
E4980AL-10K 20 Hz to 1 MHz with DCR Measurement, Handler/Scanner, ISO 17025 calibration