Description
The Keysight (Agilent) E4980AL precision LCR meter is an industry standard LCR meter that provides the best combination of accuracy, speed, and versatility for a wide range of component measurements. The frequency upgrades provide a solid investment option and asset utilization.
Offering fast measurement speed and outstanding performance at both low and high impedance ranges, the Keysight (Agilent) E4980AL is the basic tool for general R&D and manufacturing test of components and materials. LAN, USB and GPIB PC connectivity enhances your design and test productivity.
Features of the Keysight (Agilent) E4980AL Precision LCR Meter:
- Frequency: 20 Hz to 300 kHz/500 kHz/1 MHz, with 4-digit resolution in any range
- Basic accuracy: 0.05% basic accuracy with superior measurement repeat-ability at low and high impedance
- 100 uV to 2 Vrms, 1 uA to 20 mA variable test signal
- DC bias 1.5/2 V
- Auto-level control
- DC resistance
- 201 points list sweep
- Versatile PC connectivity (LAN, USB, and GPIB)
- Upgradability (frequency, handler interface, scanner interface)
Measurement Characteristics of the Keysight (Agilent) E4980AL Precision LCR Meter:
- Measurement Parameters:
- Impedance parameters |Z|, |Y|, Ls, Lp, Cs, Cp, Rs, Rp, X, G, B, D, Q, Øz [°], Øz [rad], Øy [°], Øy [rad], User defined parameter (A maximum of four parameters can be displayed at one time.)
- Measurement Range:
- Impedance parameters 140 mΩ to 4.8 kΩ (Frequency = 1 MHz, Averaging factor = 8, Measurement time mode = 3, Oscillator level = 1 dBm, Measurement uncertainty ≤ ± 10%, Calibration is performed within 23 °C ± 5 °C, Measurement is performed within ± 5 °C from the calibration temperature)
Contact TestWorld today for the best price on the Keysight (Agilent) E4980A Precision LCR Meter, 20 Hz to 2 MHz.
Explore Financial options to find a cost management solution best for your company:
Configurable Options for the Keysight (Agilent) E4980AL LCR Meter:
E4980AL-030 | 20 Hz to 300 kHz with DCR Measurement |
E4980AL-03A | 20 Hz to 300 kHz with DCR Measurement, ISO 17025 calibration |
E4980AL-03B | 20 Hz to 300 kHz with DCR Measurement, ANSI Z540 calibration |
E4980AL-03C | 20 Hz to 300 kHz with DCR Measurement, Handler |
E4980AL-03D | 20 Hz to 300 kHz with DCR Measurement, Handler, ISO 17025 calibration |
E4980AL-03E | 20 Hz to 300 kHz with DCR Measurement, Handler, ANSI Z540 calibration |
E4980AL-03F | 20 Hz to 300 kHz with DCR Measurement, Scanner |
E4980AL-03G | 20 Hz to 300 kHz with DCR Measurement, Scanner, ISO 17025 calibration |
E4980AL-03H | 20 Hz to 300 kHz with DCR Measurement, Scanner, ANSI Z540 calibration |
E4980AL-03J | 20 Hz to 300 kHz with DCR Measurement, Handler/Scanner |
E4980AL-03K | 20 Hz to 300 kHz with DCR Measurement, Handler/Scanner, ISO 17025 calibration |
E4980AL-03L | 20 Hz to 300 kHz with DCR Measurement, Handler/Scanner, ANSI Z540 calibration |
E4980AL-050 | 20 Hz to 500 kHz with DCR Measurement |
E4980AL-05A | 20 Hz to 500 kHz with DCR Measurement, ISO 17025 calibration |
E4980AL-05B | 20 Hz to 500 kHz with DCR Measurement, ANSI Z540 calibration |
E4980AL-05C | 20 Hz to 500 kHz with DCR Measurement, Handler |
E4980AL-05D | 20 Hz to 500 kHz with DCR Measurement, Handler, ISO 17025 calibration |
E4980AL-05E | 20 Hz to 500 kHz with DCR Measurement, Handler, ANSI Z540 calibration |
E4980AL-05F | 20 Hz to 500 kHz with DCR Measurement, Scanner |
E4980AL-05G | 20 Hz to 500 kHz with DCR Measurement, Scanner, ISO 17025 calibration |
E4980AL-05H | 20 Hz to 500 kHz with DCR Measurement, Scanner, ANSI Z540 calibration |
E4980AL-05J | 20 Hz to 500 kHz with DCR Measurement, Handler/Scanner |
E4980AL-05K | 20 Hz to 500 kHz with DCR Measurement, Handler/Scanner, ISO 17025 calibration |
E4980AL-05L | 20 Hz to 500 kHz with DCR Measurement, Handler/Scanner, ANSI Z540 calibration |
E4980AL-100 | 20 Hz to 1 MHz with DCR Measurement |
E4980AL-10A | 20 Hz to 1 MHz with DCR Measurement, ISO 17025 calibration |
E4980AL-10B | 20 Hz to 1 MHz with DCR Measurement, ANSI Z540 calibration |
E4980AL-10C | 20 Hz to 1 MHz with DCR Measurement, Handler |
E4980AL-10D | 20 Hz to 1 MHz with DCR Measurement, Handler, ISO 17025 calibration |
E4980AL-10E | 20 Hz to 1 MHz with DCR Measurement, Handler, ANSI Z540 calibration |
E4980AL-10F | 20 Hz to 1 MHz with DCR Measurement, Scanner |
E4980AL-10G | 20 Hz to 1 MHz with DCR Measurement, Scanner, ISO 17025 calibration |
E4980AL-10H | 20 Hz to 1 MHz with DCR Measurement, Scanner, ANSI Z540 calibration |
E4980AL-10J | 20 Hz to 1 MHz with DCR Measurement, Handler/Scanner |
E4980AL-10K | 20 Hz to 1 MHz with DCR Measurement, Handler/Scanner, ISO 17025 calibration |
E4980AL-10L | 20 Hz to 1 MHz with DCR Measurement, Handler/Scanner, ANSI Z540 calibration |