Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Teledyne LeCroy – CP030 30 A, 50 MHz Current Probe

Teledyne LeCroy – CP030 30 A, 50 MHz Current Probe

Category:

Description

The CP030 was designed with a small form factor for today?s crowded boards. The small jaw can probe currents in tight spaces and still clamp onto conductors up to 5 mm in diameter. Continuous currents of 30 Arms and peak currents of 50 A can be measured by the CP030, which also features a 50 MHz bandwidth.

Measuring AC and DC Currents

Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.

Measuring AC andDC Currents

Teledyne LeCroy current probes do notr equire the breaking of a circuitor the insertion of a shunt to make accurate and reliable currentmeasurements. Based on a combinationof Hall effect and transformertechnology, Teledyne LeCroy current probesare ideal for making accurate AC, DC,and impulse current measurements.

Fully Integrated with Oscilloscope

Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. All Teledyne LeCroy current probes are powered through the ProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate,resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for Degauss and Autozero functions to be done directly from the oscilloscope with a single button press.

Specification

Electrical Characteristics

Bandwidth (Probe Only) 2 MHz
Bandwidth (Probe Only) 2 MHz
Coupling AC 1 MΩ, DC 1MΩ, GND
Risetime (typical) 175 ns
Risetime (typical) 175 ns
Max Continuous Input Current 500 A
Max Continuous Input Current 500 A
Max Peak Current (at pw) 700 A
Max Peak Current (at pw) 700 A
Sensitivity 200 mA/div to 200 A/div
Sensitivity 200 mA/div to 200 A/div
Amplitude Accuracy ±1% of reading ±10 mA to 500 A
±2% of reading ±10 mA to 50 A
Maximum Circuit Voltage 600 V CAT II, 300 V CAT III (Insulated Wire)

Feature

  • Max Continuous Input Current: 30 A
  • Max Peak Current (at pw): 50A < 10 us
  • Minimum Sensitivity: 20 mA/div
  • Bandwidth: 50 MHz
  • Risetime (typical): < 7 ns
  • Coupling: AC, DC, GND
  • Cable Length: 2 m
  • Interface: Probus, 1 MOhm only
  • Max Conductor Size (diameter): 5 mm

Reviews

There are no reviews yet.

Be the first to review “Teledyne LeCroy – CP030 30 A, 50 MHz Current Probe”