Description
The small probe is optimized for maximum waveform fidelity, including high frequency signal components, in a rugged probe suitable for every day. The input capacitance of the probe is very low for a passive probe to minimize loading of high frequency signals. However, keeping any resonance beyond the passband also requires low inductance in the interconnections. Probes with limited interconnection accessories often force the user to extend
Teledyne LeCroy – PP007-1 Specifications
- Input Resistance: 10MOhms
- Maximum Voltage: 400 V CAT I (1250 V surge) 300 V CAT II
- Bandwidth: >500 MHz
- Attenuation: 10X
- Cable Length: 1.3 m
Teledyne LeCroy – PP007-1 FEATURES:
- Full control from oscilloscope through ProBus interface
- DC to 10 MHz bandwidth
- 100,000: 1 CMRR
- Gain of 1, 10, 100 & 1000
- Selectable upper and lower bandwidth limits
- Precision voltage generator (1822A only)
- Ideal for automotive and medical electronic