Description
The AP033 is a high-performance active differential probe. High bandwidth, excellent common mode rejection ratio (CMRR) and low-noise floor make the AP033 ideal for applications such as disk drive design and failure analysis as well as wireless and data communication design.
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. All Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for Degauss and Autozero functions to be done directly from the oscilloscope with a single button press.
Teledyne LeCroy current probes are available in a wide range of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 10 mA/div. Multiple current probes can be used together to make measurements on three-phase systems, or a single current probe can be used with a voltage probe to make accurate instantaneous power measurements. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies
Specification
Electrical Characteristics |
|
Bandwidth (Probe Only) | 50 MHz |
Coupling | AC 1 MΩ, DC 1MΩ, GND |
Risetime (typical) | 7 ns |
Max Continuous Input Current | 30 A |
Max Peak Current (at pw) | 50 A for < 10 s |
Sensitivity | 10 mA/div to 50 A/div |
Amplitude Accuracy | ±1% of reading to 15 A ±2% of reading to 30 A |
Maximum Circuit Voltage | 300 V CAT I, 150 V CAT II (Bare Conductor) |
Environmental and Safety |
|
Operating Temperature | 0 °C to 40 °C (32 °F to 104 °F) |
Humidity | ≤ 80 %relative humidity (non-condensing) |
Max Altitude | 2000 m (6562 ft) |
Physical Dimensions |
|
Cable Length | 2 m (6.6 ft) |
Maximum Conductor Size | 5 mm (0.2 in) |
Weight | 300 g (10.6 oz) |
General Characteristics |
|
Interface | ProBus |
Compatibility | All ProBus Oscilloscopes |
Reviews