Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Rohde & Schwarz UPV Audio Analyzer, 400 kHz Sampling Rate

Rohde & Schwarz UPV Audio Analyzer, 400 kHz Sampling Rate

Description

Definitions

General
Product data applies under the following conditions:

  •  Three hours storage at ambient temperature followed by 30 minutes warm-up operation
  •  Specified environmental conditions met
  •  Recommended calibration interval adhered to
  •  All internal automatic adjustments performed, if applicable

Key Features & Specifications

  • Voltage RMS, sinewave, open circuit 0.1 mV to 20 V
  • Frequency range  : 0.1 Hz to 80 kHz
  • Frequency error : ±10 ppm
  • Level error : at 1 kHz ±0.05 dB

Specifications with limits
Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable.

Specifications without limits
Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design.

Typical data (typ.)
Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value.

Nominal values (nom.)
Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production.

Measured values (meas.)
Characterize expected product performance by means of measurement results gained from individual samples.

Uncertainties
Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear.

Reviews

There are no reviews yet.

Be the first to review “Rohde & Schwarz UPV Audio Analyzer, 400 kHz Sampling Rate”