Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Keysight (Agilent) E8361A 10 MHz to 67 GHz Microwave Network Analyzer

Keysight (Agilent) E8361A 10 MHz to 67 GHz Microwave Network Analyzer

Product Documentation

Description

The standard Keysight (Agilent) E8361A 10 MHz to 67 GHz Microwave Network Analyzer is suitable for testing passive and active devices such as filters and amplifiers. Users can easily add options to test mixers, harmonics, intermodulation distortion (IMD), pulsed-RF, antennas and millimeter-wave (mmwave) components.

Features of the Keysight (Agilent) E8361A:

  • High dynamic range: 127 dB at 20 GHz at test port
  • Low trace noise: 0.002 dB rms at 1 kHz bandwidth
  • Fast measurement speed: 4.5 to 26 μsec/point
  • High stability: 0.05 dB/degrees Celsius
  • State-of-the-art calibration capabilities and wide-range of ECal modules
  • Advanced applications for mixer and pulse measurements
  • Single-ended and balanced measurements
  • 32 measurement channels, unlimited traces, and 16,001 points per channel
  • Connectivity with Open Windows XP, 6 USB connectors, LAN, and GPIB

Capabilities of the Keysight (Agilent) E8361A:

  • Mixer Measurements:
    • Conversion loss/gain, magnitude and phase
    • Input match, output match, and LO match
    • Isolation and compression
    • The two internal independent synthesizers with +13 dBm power and < 60 dBc harmonics eliminate the need for external synthesizers or components.
    • Advanced error correction
    • Patented vector-mixer calibration for measurement of absolute group delay
    • Scalar-mixer calibration (SMC) for match-corrected amplitude measurements
    • Signiicantly faster speed for ixed-IF (20 to 30 times faster than with an external source)
    • Easy-to-conigure multi-stage converter measurements
    • LO source control and LO power calibration
    • Mixer IMD
    • The simple two-step SMC calibration provides match-corrected conversion loss, error-corrected input and output match
    • Software tuning for embedded LO
  • Amplifier Measurements:
    • Gain, gain latness, reverse isolation, and return loss
    • Simple, fast, and accurate AM-AM and AM-PM compression measurements with the Gain Compression Application with 38 dB power sweep range at 20 GHz, +13 dBm output power
    • Test harmonics accurately with < 60 dBc source harmonics. No need for external filters.
    • Accurate and simple IMD using the dual sources and internal combiner, located behind the couplers, providing highly accurate and stable measurements. No need for external combiners.
    • Source corrected noise igure measurements with exceptional accuracy
    • Integrated source attenuators and receiver attenuators for measurement optimization
    • Perform all of the above measurements with one single connection using the PNA–X.
  • Pulsed-RF Measurements:
    • Wideband and narrowband detection
    • Up to four internal pulse generators
    • Up to two internal pulse modulators
    • Pulse widths as narrow as 33 ns
    • Pulse-to-pulse
    • Point-in-pulse, average pulse, and pulse-proile capability
    • No need for external components
  • Basic Measurements:
    • Insertion loss, gain, return loss, isolation, group delay, compression, both magnitude and phase
    • Connectorized, in-ixture, or on-wafer
    • Fast and accurate
    • Reliable and repeatable
    • Affordable
  • On-wafer Measurements:
    • Class of TRL calibrations for accurate measurements
    • Differential measurement capabilities with integrated multiport network analyzers
    • Accurate power control and de-embedding algorithm for device characterization
    • Compatibility with on-wafer calibration software for a total solution
  • Differential Measurements:
    • Single-ended, balanced, mixed-mode
    • S-parameters
    • Ratioed and unratioed measurements
    • Mode-conversion analysis
    • True-mode stimulus measurements
  • Multiport Measurements:
    • Multiport conigurations optimized for your device, including full cross-bar
    • Quick-Short-Open-Load-Thru (QSOLT) for fast, multiport cal
    • N-port calibration for accuracy and ease-of-measurements
    • Test-set control part of PNA irmware
    • 32 independent channels for fast measurement speed

Contact TestWorld today for the best price on a Keysight (Agilent) E8361A 10 MHz to 67 GHz Microwave Network Analyzer.

Explore Financial options to find a cost management solution best for your company:

Configurable Options for the Keysight (Agilent) E8361A:

  • E8361A-010: Time-domain capability
  • E8361A-014: Configurable test set
  • E8361A-016: Add receiver attenuators
  • E8361A-080: Frequency Offset
  • E8361A-081: Reference receiver switch
  • E8361A-082 Scalar-calibrated converter measurements
  • E8361A-083: Vector- and scalar-calibrated converter measurements
  • E8361A-084:  Embedded LO Measurements
  • E8361A-550: 4-port measurement application
  • E8361A-551: N-port capabilities
  • E8361A-H08: Pulsed-RF measurement capability
  • E8361A-H11: IF access (for antenna, pulsed-RF and mm-wave measurements)
  • E8361A-H85: High-power configurations
  • E8361A-UNL: Extended power range and bias-tees

Reviews

There are no reviews yet.

Be the first to review “Keysight (Agilent) E8361A 10 MHz to 67 GHz Microwave Network Analyzer”