Contact us: 1-855-200-TEST (8378) or sales@testworld.com

ThermoFisher Scientific (Keytek) ECAT Pulsed Immunity EMC Test System

ThermoFisher Scientific (Keytek) ECAT Pulsed Immunity EMC Test System

Product Documentation

Description

Control your regulatory program and improve product quality. The ThermoFisher Scientific (Keytek) ECAT Pulsed Immunity EMC Test System is a modular, full capability electromagnetic compatibility test platform that easily and rapidly tests for pulsed EMI threats throughout the manufacturing process, including pre-compliance, production sampling, and final compliance. The ECAT EMC Test System addresses mandatory national and international conducted immunity (EMC) standards including IEC, EN, and FCC standards, and supports specialty performance/industry requirements testing to Telcordia/CORE, UL, ANSI™, and IEEE.

ECAT systems are proven, high-volume and specialty EMC test platforms targeted to in-house and commercial test labs tasked with supporting comprehensive global product certifications. The ECAT EMC Test System is designed to fulfill the regulatory compliance and product quality/performance requirements and standards of the electronics industry and service providers:

  • Telecom/wireless
  • Medical devices
  • Consumer electronics
  • Industrial automation
  • Aerospace/military
  • Commercial EMC testing laboratories

The ThermoFisher Scientific (Keytek) ECAT Pulsed Immunity EMC Test System delivers comprehensive testing in an all-in-one architecture. The ECAT frame is populated with individual pulse generators which connect to the test product, and the ECAT system can be easily expanded or upgraded by adding new pulse generators as your product technology or test standards change. This reduces costly equipment obsolescence. The ECAT system and modules are delivered ready for immediate immunity testing and provide an unmatched level of operating ease, accuracy and safety.

ThermoFisher Scientific (Keytek) ECAT Features/Functions Include:

  • Tests for pulsed EMI hazards: EFT, Surge, PQF™ (Power Quality Failure), Magnetic Field.
  • System features designed to support CE Marking and related global EMC certifications
  • User-programmable test limits are easily created
  • All-in-one architecture is convenient for users, drives testing efficiency
  • Specialty test modules (Telcordia/CORE, 10-20kV combination surge, 100A CDN, etc)
  • Supports high-voltage, high-current, high-volume product testing
  • Long service life (20+ years) drives ROI for capital expense
  • ECAT is the “Industry Standard” – used daily in EMC labs
  • Easy-to-use Windows™-based application software allows quick implementation of international and national test routines
  • Virtual Front Panel™ retains key operating parameters during set up and testing
  • Multi-level system interlock architecture provides maximum user safety
  • Provides accurate automatic report generation
  • Features flexible, economically upgradable architecture
  • ECAT supports testing at highest level (Quality Systems compliant to ISO/IEC 17025)

Contact TestWorld today for the best price on a ThermoFisher Scientific (Keytek) ECAT Pulsed Immunity EMC Test System.

Explore Financial options to find a cost management solution best for your company:

All systems require the ECAT Model E103 Series Control Center: Computer-driven control center and power units required for the operation of any Thermo Scientific (Keytek) ECAT test system.

EFT Simulator Modules for the ThermoFisher Scientific (Keytek) ECAT:

  • ECAT Model E411: EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV
  • ECAT Model E412: EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV
  • ECAT Model E421: EFT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8kV

Surge Simulator Modules for the ThermoFisher Scientific (Keytek) ECAT:

  • ECAT Model E501B: Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA
  • ECAT Model E502B: Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT)
  • ECAT Model E503: Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
  • ECAT Model E504A: Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module)
  • ECAT Model E505A: Plug-in module that produces the lightning surge waveforms required by FCC Part 68
  • ECAT Model E506-4W: Plug-in module to produce the 2/10μs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing
  • ECAT Model E508 and E508-12P: Plug-in modules to produce the 10/360μs surges required by Telcordia GR-1089 CORE
  • ECAT Model E510A: Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA
  • ECAT Model E511: Plug-in module to provide combination waves to 6 kV and 5kA, as required by British Telecom standards
  • ECAT Model E513: Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864
  • ECAT Model E514: Surge simulator for 10/1000μs current waves
  • ECAT Model E515: Module to produce the 10/250μs surges required by Telcordia GR-1089-CORE
  • ECAT Model E518: Plug-in module to produce the 10/1000μs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT.
  • ECAT Models E521 and E522: Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for single-phase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits).

Coupler/Decouplers for the ThermoFisher Scientific (Keytek) ECAT:

  • ECAT Model E551: A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5.
  • ECAT Model E455x: Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5
  • ECAT Models EP61 and EP62: Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A