Contact us: 1-855-200-TEST (8378) or sales@testworld.com

Teseq NSG 3040 4kV Conducted Immunity Generator for IEC 61000-4-4, IEC 61000-4-5 and more.

Teseq NSG 3040 4kV Conducted Immunity Generator for IEC 61000-4-4, IEC 61000-4-5 and more.

Product Documentation

Description

4 kV is the highest test level for transients testing required in the basic standards of the IEC 61000-4-x series (IEC 61000-4-4 & IEC 61000-4-5 being most common) as well as in the multitude of resulting product standards for any equipment used in indoor locations. The Teseq NSG 3040 series always offers a minimum of 10% more than the highest required level, and is ideally suited to test the following types of equipment:

  • Household Appliances
  • Industrial Machines
  • Laboratory Equipment
  • Lighting Devices
  • Information Technology
  • Portable Tools
  • Medical Instruments
  • Electric Vehicles

Teseq’s new NSG 3040 is an easy-to-use multifunction generator that simulates electromagnetic interference effects for immunity testing in conformity with international, national and manufacturers’ standards including the latest IEC/EN standards. The Teseq NSG 3040 system is designed to fulfill conducted EMC test requirements for CE mark testing, including Combination Wave Surge (4.4 kV) for IEC 61000-4-5, Electrical Fast Transient (EFT) pulses (4.8 kV) for IEC 61000-4-4 and Power Quality Testing (PQT) for IEC/EN 61000-4-11 & IEC/EN 61000-4-29. Expansion capabilities enable the system to be configured for a much broader range of applications including Telecom Surge 10/700 and Magnetic Field tests.

Featuring an innovative modular design, the NSG 3040 is a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories. Teseq’s well proven “Master-Slave” architecture enables individual pulse modules to be calibrated separately, with calibration data and correction factors stored on the slave controller. New modules can be easily installed with no need to return the entire system for calibration.

Depending on your exact testing needs, different models are available to ensure the NSG 3040 is configured to your exact testing requirements. Contact TestWorld today for the best price on a Teseq NSG 3040 4kV Conducted Immunity Generator for IEC 61000-4-4, IEC 61000-4-5 and more.

Explore Financial options to find a cost management solution best for your company:

Common Configurations available for the Teseq NSG 3040:

  • Teseq NSG 3040-IEC: Multi-function generator for immunity testing in accordance with EN/IEC 61000-4-4, EN/IEC 61000-4-5 and EN/IEC 61000-4-11 consisting of: Mainframe NSG 3040, 7” color touch panel display, CWM 3450, FTM 3425, PQM 3403, 260V/16A single phase CDN, LAN (TCP/IP) interface, cables, traceable calibration certificate. WIN 3000 basic software included.
  • Teseq NSG 3040-DDV: NSG 3040 for EN/IEC 61000-4-11 testing only. Includes 7” color touch panel display, PQM 3403, 260V/16A single phase CDN, LAN (TCP/IP) interface, cables, traceable calibration certificate. WIN 3000 basic software included.
  • Teseq NSG 3040-EFT-CWS-EPO: Multi-function generator for immunity testing in accordance with EN/IEC 61000-4-4 and EN/IEC 61000–4-5 with no internal CDN (for use with external 3-phase CDN) consisting of: Mainframe NSG 3040, 7” color touch panel display, CWM 3450, FTM 3425, LAN (TCP/IP) interface, cables, traceable calibration certificate. WIN 3000 basic software included.
  • Teseq NSG 3040-SOW: Stand-alone generator for immunity testing in compliance with EN/IEC 61000-4-18 and ANSI C37.90.1 for single phase equipment up to 270V/16A. 7” color touch panel display, LAN (TCP/IP) interface, cables, traceable calibration certificate. WIN 3000 basic software included.

Configure Transient Modules for your Teseq NSG 3040:

  • CWM 3450:Surge generator module according to IEC 61000-4-5. Open-circuit voltage from 200 to 4.4kV. Output impedance 2 or 12 Ohms. Includes traceable calibration certificate.
  • FTM 3425: EFT generator module according to IEC 61000-4-4. Open-circuit voltage from 200 to 4.8kV/1MHz. Output impedance 50 Ohms. Includes traceable calibration certificate.
  • PQM 3403: Power Fail generator module according to IEC 61000-4-11 & -29. EUT current up to 16A cont. Phase angle synchronization 0 – 359 degrees in 1 degree steps. Includes traceable calibration certificate.

Coupling / Decoupling Network Options for your Teseq NSG 3040:

  • CDN 3043-C32 3-Phase 480V/32A CDN for NSG 3040. Couples EFT pulses to 4.8kV and surge pulses to 4.4kV. Includes traceable calibration certificate, user manual and cables.
  • CDN 3043-S32 3-Phase 480V/32A CDN for NSG 3040. Couples surge pulses to 4.4kV. Includes traceable calibration certificate, user manual and cables.
  • CDN 3043-B32 3-Phase 480V/32A CDN for NSG 3040. Couples EFT pulses to 4.8kV. Includes traceable calibration certificate, user manual and cables.
  • CDN 117-M: CDN for unbalanced 2-wire Data Lines includes coax cables for Modula and NSG 3xxx
  • CDN 118-M: CDN for 2-pairs of balanced Data Lines includes coax cables for Modula and NSG 3xxx
  • CDN-HSS-2: New CDN for surging up to 8 lines of high speed balanced Data Lines to 1000MHz according to draft EN 61000-4-5 with 1.2/50us combination wave pulses up to 2kV. Coupling is via 40Ω resistors in series with a capacitor, max surge current 50A

Additional Accessories for CE Mark Testing with the Teseq NSG 3040:

  • CDN 3425: Data Line Capacitive Coupling Clamp without safety interlock, replaces CDN 8014
  • INA 3825: Data Line EFT capacitive coupling clamp cover w/safety interlock
  • INA 6501: Step transformer 0%,40%,70%,80%,100% for switched voltage variations (manual setting of dip level), 16A.
  • INA 6502: Program controlled step transformer 0%,40%,70%, 80%, 100% for switched voltage variations (manual preset), 16A. Fully automatic operation via Win3000 software.
  • INA 701: 1m x 1m magnetic field coil for power line magnetic fields up to 4A/m, requires MFO 6501or MFO 6502, includes cable to MFO 650x
  • INA 702: 1m x 1m magnetic field coil for power line magnetic fields up to 40A/m, requires MFO 6501 or MFO 6502, includes cable to MFO 650x
  • INA 703: 1m x 1m magnetic field coil for power line magnetic fields up to 120A/m, with MFO 6501 or MFO 6502, or up to 330A/m with NSG 1007 series source. Requires INA 3251 cable.
  • MFO 6501: Stand-alone generator unit for power line frequency magnetic tests with antennas INA 701 or INA 702. Requires user supplied Ampmeter.
  • MFO 6502 Interface and amplifier unit for power line frequency magnetic tests with antennas INA 701 or INA 702. Fully automatic operation via Win3000 software.

Reviews

There are no reviews yet.

Be the first to review “Teseq NSG 3040 4kV Conducted Immunity Generator for IEC 61000-4-4, IEC 61000-4-5 and more.”