Description
Vector Network Analyzer R&S ZVB covering the frequency range from 300 kHz to 8 GHz and 10 MHz to 20 GHz has been designed for universal measurements on passive and active components. Especially for multiport measurements and measurements on balanced devices the R&S ZVB simplifies vector analysis. Featuring comprehensive measurement functions, outstanding specifications, high measurement and data transfer speeds plus remote-control capability, the R&S ZVB is the ideal instrument for both development and production. The highly compact instrument weighs less than 20 kg and is 44 cm x 23 cm x 35 cm in size. New multiport concept Instruments with 2,3 and 4 ports Multiport capability Ability of balanced measurements Calibration units available Outstanding specifications 20 001 points per trace Dynamic range better than 123 dB Power sweep range 50 dB High speed Measurement time < 4.5 ms for 201 points (freq. sweep) Switching between channels < 1 ms Switching between setups < 10 ms Data transfer time < 0.7 ms (201 points via RSIB) Simultaneous measurement of more than one DUT Modern user interface Intuitive Windows-based mouse operation Operation using hardkeys and softkeys number of channels and traces
Key Facts
- Short measurement times
- Wide dynamic range
- High output power
- Wide power sweep range
Features
- High performance for fast and reliable measurements
- Ergonomic user interface
- Advanced measurement functionality
Specifications
Measurement time per point | CW mode, at 500 kHz IF bandwidth | < 4.5 μs |
Measurement time (including any data transfer time) |
201 measurement points, measurement bandwidth 500 kHz, display off, ALC off, at 5 GHz, narrow span |
< 4.5 ms |
Data transfer time | data transfer simultaneous with measurement | |
Dynamic range | at 10 Hz IF bandwidth | > 120 dB |
Inherent noise | < –110 dBm | |
Power sweep range1) | –40 dBm to +13 dBm | |
IF bandwidths | 1 Hz to 500 kHz | |
Number of measurement points per trace | 1 to 60 001 | |
Platform | ||
Number of test ports | 2 or 4 | |
Number of measurement and reference receivers | one measurement and one reference receiver per test port |
|
Number of integrated generators | one generator per test port pair | |
Calibration techniques | TOSM, UOSM, TRL/LRL, TOM, TRM, TNA, automatic calibration unit |
|
Operating system and internal PC | Windows XP | |
Operation | hardkeys/softkeys, keyboard and mouse, online help system, measurement and calibration wizard |
|
Number of traces, diagrams, independent channels, setups that can be simultaneously loaded into RAM | > 1002), traces can be assigned to diagrams as required |
Reviews