Description
Features of the Keysight (Agilent) N5230C:
- 300 kHz to 6/13.5/20 GHz and 10 MHz to 20/40/50 GHz
- 2- or 4- ports with two built-in sources
- 110 dB system and 122 dB receiver dynamic range, 32,001 points, 32 channels
- < .006 dB rms (Option 22x)
- Measurement speed: 4 to 9 µs per point
Capabilities of the Keysight (Agilent) N5230C:
- Mixer Measurements:
- Conversion loss/gain, magnitude and phase
- Input match, output match, and LO match
- Isolation and compression
- The two internal independent synthesizers with +13 dBm power and < 60 dBc harmonics eliminate the need for external synthesizers or components.
- Advanced error correction
- Patented vector-mixer calibration for measurement of absolute group delay
- Scalar-mixer calibration (SMC) for match-corrected amplitude measurements
- Signiicantly faster speed for ixed-IF (20 to 30 times faster than with an external source)
- Easy-to-conigure multi-stage converter measurements
- LO source control and LO power calibration
- Mixer IMD
- The simple two-step SMC calibration provides match-corrected conversion loss, error-corrected input and output match
- Software tuning for embedded LO
- Amplifier Measurements:
- Gain, gain latness, reverse isolation, and return loss
- Simple, fast, and accurate AM-AM and AM-PM compression measurements with the Gain Compression Application with 38 dB power sweep range at 20 GHz, +13 dBm output power
- Test harmonics accurately with < 60 dBc source harmonics. No need for external filters.
- Accurate and simple IMD using the dual sources and internal combiner, located behind the couplers, providing highly accurate and stable measurements. No need for external combiners.
- Source corrected noise igure measurements with exceptional accuracy
- Integrated source attenuators and receiver attenuators for measurement optimization
- Perform all of the above measurements with one single connection using the PNA–X.
- Pulsed-RF Measurements:
- Wideband and narrowband detection
- Up to four internal pulse generators
- Up to two internal pulse modulators
- Pulse widths as narrow as 33 ns
- Pulse-to-pulse
- Point-in-pulse, average pulse, and pulse-proile capability
- No need for external components
- Basic Measurements:
- Insertion loss, gain, return loss, isolation, group delay, compression, both magnitude and phase
- Connectorized, in-ixture, or on-wafer
- Fast and accurate
- Reliable and repeatable
- Affordable
- On-wafer Measurements:
- Class of TRL calibrations for accurate measurements
- Differential measurement capabilities with integrated multiport network analyzers
- Accurate power control and de-embedding algorithm for device characterization
- Compatibility with on-wafer calibration software for a total solution
- Differential Measurements:
- Single-ended, balanced, mixed-mode
- S-parameters
- Ratioed and unratioed measurements
- Mode-conversion analysis
- True-mode stimulus measurements
- Multiport Measurements:
- Multiport conigurations optimized for your device, including full cross-bar
- Quick-Short-Open-Load-Thru (QSOLT) for fast, multiport cal
- N-port calibration for accuracy and ease-of-measurements
- Test-set control part of PNA irmware
- 32 independent channels for fast measurement speed
Contact TestWorld today for the best price on a Keysight (Agilent) N5230C PNA-L Microwave Network Analyzer.
Explore Financial options to find a cost management solution best for your company:
Configurable Options for the Keysight (Agilent) N5230C:
- N5230C-020: 300 kHz–6 GHz 2-port standard test set
- N5230C-025: 300 kHz–6 GHz 2-port configurable test set and extended power range
- N5230C-120: 300 kHz–13.5 GHz 2-port standard test set
- N5230C-125: 300 kHz–13.5 GHz 2-port configurable test set and extended power range
- N5230C-140: 300 kHz–13.5 GHz 4-port standard test set
- N5230C-145:300 kHz–13.5 GHz 4-port configurable test set and extended power range
- N5230C-146: 300 kHz–13.5 GHz 4-port configurable test set, extended power range and internal second source (Option 080 recommended)
- N5230C-220: 10 MHz–20 GHz 2-port standard test set
- N5230C-225: 10 MHz–20 GHz 2-port configurable test set and extended power range
- N5230C-240: 300 kHz–20 GHz 4-port standard test set
- N5230C-245: 300 kHz–20 GHz 4-port configurable test set and extended power range
- N5230C-246: 300 kHz–20 GHz 4-port configurable test set, extended power range and internal second source (Option 080 recommended)
- N5230C-420: 10 MHz–40 GHz 2-port standard test set
- N5230C-425: 10 MHz–40 GHz 2-port configurable test set and extended power range
- N5230C-520: 10 MHz–50 GHz 2-port standard test set
- N5230C-525: 10 MHz–50 GHz 2-port configurable test set and extended power range
Measurement applications
- N5231C-010: Time domain for 6 GHz model
- N5230C-010: Time domain for 13.5, 20, 40 or 50 GHz model
- N5230C-080: Frequency offset measurements
- N5230C-082: Scalar-calibrated converter measurements (Option 080 required)
- N5230C-550: 4-port measurement application (Not available on 4-port models. Requires test set Option xx5 or xx6)
- N5231C-551: N-port capabilities for 6, 13.5 or 20 GHz model (Requires test set Option xx5 or xx6)
- N5230C-551:N-port capabilities for 40 or 50 GHz model (Requires test set Option xx5 or xx6)
Reviews