Contact us: 1-855-200-TEST (8378) or sales@testworld.com

California Instruments L-Series Precision AC Power Sources

California Instruments L-Series Precision AC Power Sources

Product Documentation

Description

Now you can test any product that operates from AC power with the most compact, versatile power source in the test industry. The California Instruments L-Series Precision AC Power Sources’ small size provides more power per inch than most other AC supplies. Highly efficient, these products dissipate less heat than previous generation systems and allow up to an additional 10 % output power. With a programmable controller, L-Series models provide the most comprehensive set of programmable functions in the industry. Automatic remote calibration and comprehensive self-tests simplify maintainability.

All California Instrumentes L Series units are completely self-contained. Control is through an embedded oscillator, factory configured to your specific requirements. Output parameters are controlled via the front panel or the IEEE-488 bus. Bus programming, standard with -P, -PT, allows programming and measurement function readback compatible with a number of other standards including VXI, MXI and RS232 via recommended translators. To simplify programming, the standard unit supports both Abbreviated Plain English programming and an ATLAS-based control language.

For avionics applications, any 3-phase model can be configured with 26 V and 5 V auxiliary outputs. (AX option)

The California Instruments L-Series Precision AC Power Sources are ideal for applications where small size, low heat dissipation and light weight are important. These include DC power supply testing, production test, quality assurance verification, engineering and ATE.

Features of the California Instruments L-Series:

  • Single phase, three phase and split phase configurations
  • Mode option allows switching between single and three phase output
  • Output frequency range up to 5000 Hz
  • Full output VA with 0 to 1 power factor
  • High peak current capability with up to 9:1 crest factor
  • Efficiency 75% typical or better. Generates less heat and consumes less power

Specifications of the California Instruments L-Series:

  • Output Voltage :
    • Standard 0-135 V, L-N, 0-270 V, L-N
    • -HV Option 0-156 V, L-N, 0-312 V, L-N
    • -LV Option 0-67.5 V, L-N, 0-135 V, L-N
    • -EHV Option 0-200 V, L-N, 0-400 V, L-N
  • Output Frequency:
    • Models 1503L, 2001L, 2750L-3, 4500L-3 and 6000L-3: 17 Hz to 5 kHz
    • Models 2750L-1, 4500L-1, 9000L and 13500L: 17 Hz to 2 kHz
    • Models 6000L-1, 12000L and 18000L: 17 Hz to 440 Hz
    • All models with -PT controller 17 Hz to 550 Hz except 6000L, 12000L and 18000L
  • Input:
    • Models 1503L, 2001L 115 V or 230 V single phase, 47 Hz to 440 Hz
    • Models 2750L, 4500L, 9000L, 13500L 187 V – 252 V, L-L, 3 phase / (230 V single phase for model 2750L only) 342 V – 456 V, L-L, 3 phase with -UP option
    • Models 6000L, 1200L, 18000L 208 V – 252 V, L-L, 3 phase
    • Model 2750L 1 or 3 phase input 187 – 252 V
  • Total Harmonic Distortion:
    • 45 Hz to 2 kHz: 1 percent
    • To 5 kHz: 2 percent
    • 50/60 Hz: 0.5 percent typical
  • AC Noise Level 160 mV rms typical
  • Connectors
    • Input provided on rear terminal block
    • Output provided on rear terminal block (Remote sense mating connectors are provided)
  • Protection
    • Overcurrent
    • Overpower
    • Short circuit
    • Overtemperature
    • Current limit trip standard with programmable units. All units have adjustable current limit.

Contact TestWorld today for the best price on a California Instruments L-Series Precision AC Power Source.

Explore Financial options to find a cost management solution best for your company:

Models for the California Instruments L-Series:

  • California Instruments 1503L
    • Power Out: 1667 VA
    • Phase: 3
    • Current in 135 Volt Range:
      • A rms: 4.1 / ø
      • A peak (Repetitive peat current capability): 9.3 / ø
      • A peak (Non repetitive pear inrush current): 10 / ø
    • Current / phase in 3 Phase mode: 4.1 / ø
  • California Instruments 2001L
    • Power Out: 2000 VA
    • Phase: 1
    • Current in 135 Volt Range:
      • A rms: 14.8 / ø
      • A peak (Repetitive peat current capability): 55.6 / ø
      • A peak (Non repetitive pear inrush current): 60 / ø
  • California Instruments 2750L
    • Power Out:  3000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 22.2 / ø
      • A peak (Repetitive peat current capability):  83.3 / ø
      • A peak (Non repetitive pear inrush current): 90 / ø
    • Current / phase in 3 Phase mode: 7.4 / ø
  • California Instruments 4500L
    • Power Out:  5000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 37 / ø
      • A peak (Repetitive peat current capability):  83.3 / ø
      • A peak (Non repetitive pear inrush current): 90 / ø
    • Current / phase in 3 Phase mode: 12.3 / ø
  • California Instruments 6000L
    • Power Out:  6000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 44.4 / ø
      • A peak (Repetitive peat current capability):  157.4 / ø
      • A peak (Non repetitive pear inrush current): 170 / ø
    • Current / phase in 3 Phase mode: 14.8 / ø
  • California Instruments 9000L
    • Power Out:  9000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 74 / ø
      • A peak (Repetitive peat current capability):  166.7 / ø
      • A peak (Non repetitive pear inrush current): 180 / ø
    • Current / phase in 3 Phase mode: 24.7 / ø
  • California Instruments 12000L
    • Power Out:  12000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 90 / ø
      • A peak (Repetitive peat current capability):  314.8 / ø
      • A peak (Non repetitive pear inrush current): 340 / ø
    • Current / phase in 3 Phase mode: 30 / ø
  • California Instruments 13500L
    • Power Out:  15000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 111.2 / ø
      • A peak (Repetitive peat current capability):  250 / ø
      • A peak (Non repetitive pear inrush current): 270 / ø
    • Current / phase in 3 Phase mode: 37 / ø
  • California Instruments 18000L
    • Power Out:  18000 VA
    • Phase: 1 or 3
    • Current in 135 Volt Range:
      • A rms: 133.2 / ø
      • A peak (Repetitive peat current capability):  472 / ø
      • A peak (Non repetitive pear inrush current): 510 / ø
    • Current / phase in 3 Phase mode: 44.4 / ø

 