Description
See things both ways—infrared and visual (visible light) images combined together communicating critical information faster and easier—traditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and combines it together, taking the mystery out of IR image analysis. IR-Fusion is standard on Fluke Ti10.
Feature
- Enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images.
- Optimized for field use in harsh work environments.
- Engineered and tested to withstand a 2 m (6.5 ft) drop – ;When was the last time you dropped a tool?
- Withstands dust and water—tested to an IP54 rating.
- Delivers the clear, crisp images needed to find problems fast.
- Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).
- Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
- Reflected background temperature (reflected temperature compensation)
- No need to carry pen and paper—record findings by speaking into the camera. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
- Everything needed to get started is included.
Training DVD is now included free. See how easy it is to set up your thermal imager, create professional reports with SmartView software and learn thermography theory with step-by-step video instructions. - Adjustable hand strap for left-or right-handed use.
Model Name | Description | |
---|---|---|
Fluke Ti10 | Fluke Ti10 Infrared Camera | |
Includes:
|
Specification
Temperature | |
Temperature measurement range (not calibrated below -10°C) | -20°C to +350°C (-4°F to + 662°F) (two ranges) |
Temperature measurement accuracy | ± 2°C or 2% (whichever is greater) |
On-screen emissivity correction | Yes |
Imaging Performance | |
Field of view | 23° x 17° |
Spatial resolution (IFOV) | 2.5 mRad |
Minimum focus distance | Thermal lens: 15 cm (6 in) Visible (visual) light lens: 46 cm (18 in) |
Focus | Manual |
Image frequency | 9 Hz refresh rate |
Detector type | 160 X 120 focal plane array, uncooled microbolometer |
Infrared lens type | 20 mm F = 0.8 lens |
Thermal sensitivity (NETD) | ≤ 0.09°C at 30°C target temp. (90 mK) |
Infrared spectral band | 7.5 μm to 14 μm |
Visual camera | 640 x 480 resolution |
Reviews